HID’s ProxPoint® Plus reader combines multiple configuration options with an attractive, inconspicuous design and economical price. Its secure potted electronics are ideal for both indoor and outdoor applications.
  • Small sized, low cost reader features a beeper and multicolor LED which can be host and/or locally controlled.
  • Potted reader suitable for indoor or outdoor use.
  • 18″ (45 cm) wire pigtail standard; consult factory for 9′ (2.7 m) pigtail available by special order.
  • Classic Series covers available in black, gray, white or beige. Designer Series covers available in black or gray.

Key Features:

  • Features a beeper and multicolor LED which can be host and/ or locally controlled.
  • Enables various beeper and LED configurations, depending on individual site requirements.
  • Can read HID cards with formats up to 85 bits.
  • Designed for mounting directly onto metal with no change in read range performance.
  • Available with either Wiegand or Clock-and-Data (magnetic stripe data) output.
  • Compatible with all standard access control systems.
  • Aesthetic design available in two cover designs and in four colors to match any decor.
  • Includes multilingual installation manual.

Typical maximum* read range:

  • ProxCard® II Card – up to 3″ (7.6 cm)
  • ISOProx® II card – up to 2.5″ (6.35 cm)
  • DuoProx® II Card – up to 2.5″ (6.35 cm)
  • Smart ISOProx®/DuoProx® II Cards – up to 2.5″ (6.35 cm)
  • Proximity & MIFARE® Card – up to 2.5″ (6.35 cm)
  • ProxCard Plus® Card – up to 1.0″ (2.5 cm)
  • ProxKey® II Keyfob – up to 1.5″ (3.8 cm)
  • MicroProx® Tag – up to 2″ (5.1 cm)

*Depending on local installation conditions.

Dimensions
3.135″ x 1.720″ x 0.660″ (7.96 x 4.37 x 1.68 cm)

Power Supply:

  • 5-16 VDC
  • Linear power supplies are recommended.

Maximum Current Requirements:

  • Current (DC)
  • Average 30 mA, Peak 75 mA

Operating Temperature
-22º to 150º F (-30º to 65º C)

Operating Humidity
0-95% relative humidity noncondensing

Weight
2.7 oz. (75 gm)

Current Requirements
20mA avg / 75mA peak at 12VDC

Cable Distance:

  • Wiegand or Clock-and-Data interface:
  • 500 feet (150 m)
  • Recommended cable is ALPHA 1295 (22 AWG) 5 conductor stranded with overall shield or equivalent.

Certifications:

  • Canada/UL 294 Listed
  • FCC Certification, United States
  • Canada Certification
  • EU and CB Scheme Electrical Safety (EN60950 and IEC60950 ITE Electrical Safety)
  • Fifteen EU Countries under the R&TTE Directive (EN 300 330 – SRD, and ETS 300 683 – EMC)
  • CE Mark
  • Australia C-Tick, New Zealand
  • Taiwan, China